Titanium Tibial Part
Titanium Tibial Part is the principal structural implant used in total knee arthroplasty (TKA) and the most essential replacement component for the proximal tibial articular surface. The implant is produced from medical-grade titanium alloys, for example Gr1, Gr2, Gr3 and Gr23. These alloys are biocompatible, have good physiological corrosion resistance and a low Young’s modulus of roughly 110 GPa. Its mechanical properties are close to those of human cortical bone, which may effectively diminish the stress shielding effect and help to regenerate the bone in a long-term stable manner. Sunrui Titanium has 60 years of professional knowledge in titanium manufacturing, offering product castings with minimum wall thickness 0.4mm, single-piece weights from 0.1kg to 100kg and surface roughness up to Ra3.2μm. All goods conform to YY0117.1-2005,ASTM B367 and other related regulations of the medical sector.
The long-term clinical impact of orthopedic implants depends on the performance of materials. Medical titanium alloy has advantages over standard cobalt-chromium alloys in numerous fundamental clinical indications.
The low elastic modulus of titanium greatly decreases the problem of stress shielding. This is contrasted to conventional implants which are overly rigid and are subject to mechanical stress leading to gradual bone resorption and loosening. Titanium implants may transfer physiological load equally on the tibial plateau and maintain bone vitality and stability in the long term after surgery.
On the titanium surface, a thick and self-regenerating passive oxide coating of TiO2 is naturally produced. This coating is resistant to corrosion under human physiological saline conditions, maintaining the long-term structural integrity of implants for decades of use in the body. Titanium, however, does not contain nickel or chromium and is thus a safer alternative for those with metal allergies.
Also it has osseointegration performance that is the essential to secure long term fixation. We provide Vacuum Plasma Spray (VPS) coating and 3D porous trabecular structure treatment with porosity regulated at 60%-80%. The improved surface microstructure enables the bone tissue to grow inward and achieve stable biological fixation, which reduces the dependency on the bone cement and reduces the danger of postoperative loosening of the implant.
| Parameter | Details |
|---|---|
| Grade | Gr1, Gr2, Gr3, Gr23 |
| Min. Casting Wall Thickness | 0.4 mm |
| Max. Casting Size | φ1500mm × 600mm |
| Casting Weight | 0.1 ~ 100 kg |
| Surface Roughness | Ra 3.2 ~ 6.3 μm |
| Young's Modulus | ~110 GPa |
| Executive Standards | BMS 7-310, BMS 7-336, ASTM B367, GB/T 15073, GB/T 6614, GJB 2896A-2007, YY0117.3-2005, YY0117.1-2005 |
Our custom Titanium Tibial Part castings achieve stable and balanced performance in mechanical properties, biological safety and dimensional accuracy, fully meeting the high-standard requirements of medical implant manufacturing.
High Strength & Lightweight Design: Titanium’s specific strength effectively reduces the overall weight of tibial implants, alleviating patient limb fatigue and improving postoperative mobility and recovery efficiency, which is more suitable for young and active patients with long-term service demands.
Fatigue & Creep Resistance: Tibial implants must endure millions of cycle gait stresses in long-term in-body usage. Fatigue testing are performed on our products according to ASTM F1800 with more than 10 million cycle load verifications to ensure stable structural integrity for long-term physiological alternating loads.
Micron Level Dimensional Stability: All the tibial components are tested by professional coordinate measuring machines (CMM) to reach the ultra high dimensional tolerance precision. The precise size matching allows for a stable assembly of the polyethylene bearings and a tight fit between the implant and the bone interface, which prevents postoperative displacement and loosening.
Zero Alpha Case Surface Treatment: Medical implants have to be free from brittle oxygen-enriched alpha case layer. We choose precision casting and heat treatment procedure to totally remove the surface alpha case, which is confirmed by metallographic detection and ensures the safety and reliability of implant in use.
Sunrui Titanium fully closed-loop controls each batch of medical tibial castings. From titanium sponge raw materials to final goods, we set up raw material and manufacturing traceability records, attaining full batch information traceability.
All products are rigorously tested for surface integrity, coating bond strength under ASTM F1147 and F1044, and complete biocompatibility verification to ISO 10993. The tests for cytotoxicity and systemic toxicity are completely addressed to guarantee that all goods fulfill medical safety requirements.
The firm possesses authoritative international certifications including AS9100, NADCAP, PED, ABS, TUV and NORSOK, and provides certified papers and traceability systems to serve global medical device manufacturers in standardized procurement and OEM collaboration.

Primary Cementless TKA Surgery: The porous surface structure is ideal for youthful and active patients, facilitating bone ingrowth and biological fixation. It eliminates the excessive dependence on bone cement, thus minimizing the long-term loosening rate of the implant and enhancing the postoperative service life.
Complex Knee Revision Surgery: In cases of revision surgery with substantial bone loss and unequal stress, the Titanium Tibial Part may be combined with modular support and filling accessories. It has fatigue resistance, and can adjust to complicated and irregular load circumstances to provide steady surgical result.
Patient-Specific Custom Implants (PSI) : We assist the individualized customization of the goods with integrated 3D lattice porous structures for patients with severe knee anatomical abnormalities. We may achieve one-to-one exact implant fabrication for each patient's circumstances by using the malleable processing capabilities of titanium.
We offer expert OEM support services to the worldwide orthopedic medical device makers, with completely adjustable casting form, titanium grade, wall thickness and surface process parameters to meet customers’ design requirements.

Q1: Why choose titanium tibial implants instead of cobalt-chrome materials?
A1: Titanium features lower elastic modulus to minimize stress shielding and protect bone tissue. It is nickel-chromium free with higher biocompatibility, effectively avoiding metal allergy risks and delivering better long-term clinical stability.
Q2: How do the products achieve bone ingrowth and biological fixation?
A2: We adopt VPS spraying or 3D porous lattice technology to form a 60%–80% high-porosity microstructure on the implant surface, which allows bone tissue to grow inward and form stable biological bonding fixation.
Q3: Are titanium tibial components suitable for cemented surgery?
A3: Yes. Our products support both cementless and cemented fixation modes. Individual designs are equipped with cement grooves to mechanical engagement, adapting to different surgical clinical needs.
Q4: Is the titanium tibial implant compatible with MRI examination?
A4: Titanium is non-ferromagnetic with zero magnetic attraction risk. It is fully MRI-safe and will not cause equipment safety hazards or obvious imaging interference for patients.
Q5: What customization services can be provided for medical OEM clients?
A5: We support customized selection of Gr1/Gr2/Gr3/Gr23 grades, personalized casting geometry, minimum 0.4mm thin-wall casting, exclusive surface treatment and dimensional tolerance customization with complete certification documents.

If you are looking for high-precision, clinically Titanium Tibial Part to enrich your orthopedic implant product line, please contact our professional technical team via srt@sunrui-ti.com.